Victron Quattro 48 Volt / 5000 VA Pure Sine Wave Inverter with 70 Amp Charger

More Views

Victron Quattro 48 Volt / 5000 VA Pure Sine Wave Inverter with 70 Amp Charger

SKU: VIC-QTRO-48-5K
Model 48/5000/100-100 / Part # QUA485021100

Availability: In stock

$2,542.35
Product Description

    Details

    The Victron MultiPlus and Quattro series of pure sine wave inverter-chargers are some of the most feature-rich models we've seen. Besides being well-made, compact, and affordable, they do it all. Their primary features are:

    • Stackable for single phase, split phase, or three phase service.
    • Integrated transfer switches (Quattro models will select from two AC inputs).
    • High output dual bank battery charger, which can be regulated to accommodate small generators.
    • Power Assist, which supplements generator or shore power with inverter power when load requires.
    • Extensive remote monitoring and control availability.
    • Configurable with PC, remote panel, or DIP switches.

    For more information, see the links to the Victron documentation below. For connecting to the Color Control GX Display or NEMA2000, see the Victron Cables and Adapters.

    Multi-functional, with intelligent power management

    The Victron Quattro differs from the MultiPlus primarily in it's ability to be connected to two independent AC sources, for example shore-side power and a generator, or two generators. The Quattro will automatically connect to the active source. As with the MultiPlus, it is a powerful true sine wave inverter, and includes a sophisticated battery charger with adaptive charge technology and a high-speed AC transfer switch in a single compact enclosure. In addition to these primary functions, the Quattro has several advanced features, as detailed below.

    Two AC Outputs
    The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater for example, can be connected to this output (second output available on models rated at 3kVA and more).

    Virtually unlimited power thanks to stackability
    Up to six Multi's can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity.

    Three phase capability
    In addition to parallel connection, three units can be configured for three-phase output. With three strings of six parallel units a 45kW / 54kVA three phase inverter and 1260A charger can be built.

    Split phase options
    Two units can be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30kW / 36kVA of split phase power. Or, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240V / 60Hz.

    PowerControl - Dealing with limited generator, shore side or grid power
    The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (nearly 20A per 3kVA MultiPlus at 120VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

    PowerAssist, or Hybrid Operation - Boosting the capacity of shore or generator power
    This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the external source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Four stage adaptive charger and dual bank battery charging
    The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on the Victron website, under Technical Information. In addition to this, the MultiPlus will trickle charge a second battery with an independent output intended for a main engine or generator starter battery.

    System configuration is incredibly easy
    After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new advanced features.

    Reliability
    All Victron products (except batteries) come with a 5 year worldwide warranty, supported by an international network of service points and dealers.

     Victron Quattro example

     Quattro 12/5000/200 - 100/100 120V 24/5000/120 - 100/100 120V 48/3000/35 - 50/50 120V 48/5000/70 - 100/100 120V
    Power Control / PowerAssist Yes
    Transfer switch Yes
    AC Inputs (2x) Input voltage range: 90-140 VAC Input frequency: 45 – 65 Hz Power factor: 1
    Maximum feed through current (A) 2 x 100 2 x 100 2 x 50 2 x 100
    INVERTER        
    Input voltage range (V DC) 9.5 – 17 V 19 - 33 V 37.2 - 64.4 37.2 - 64.4
    Output Output voltage: 120 VAC ± 2%    Frequency: 60 Hz ± 0,1% (1)
    Cont. output power at 77 °F (VA) (3) 5000 5000 3000 5000
    Cont. output power at 77 °F (W) 4000 4000 2400 4000
    Cont. output power at 104 °F (W) 3700 3700 2200 3700
    Cont. output power at 105 °F (W) 3000 3000 1700 3000
    Peak power (W) 10000 10000 6000 10000
    Maximum efficiency (%) 94 94 94 95
    Zero-load power (W) 30 30 25 35
    Zero load power in AES mode (W) 20 25 20 30
    Zero load power in Search mode (W) 10 10 12 15
    CHARGER        
    Charge voltage 'absorption' (V DC) 14.4 28.8 57.6 57.6
    Charge voltage 'float' (V DC) 13.8  27.6 55.2 55.2
    Storage mode (V DC)  13.2  26.4 52.8 52.8
    Charge current house battery (A) (4)  200 120  35 70
    Charge current starter battery (A) 4 4 n/a n/a
    Battery temperature sensor   Yes
    GENERAL        
    Auxiliary output (A) (5) 50 50 32 50
    Programmable relay (6)  Yes (3x)  Yes (3x)  Yes (3x)  Yes (3x)
    Protection (2)   a-g
    VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration  
    General purpose com. port (7) Yes (2x)
    Remote on-off Yes
    Common Characteristics Operating temp. range: -40 - 150°F (fan assisted cooling)
    Humidity (non condensing): max 95%  
    ENCLOSURE        
    Common Characteristics Material & Color: aluminum (blue RAL 5012) Protection category: IP 21
    Battery-connection Four M8 bolts (2 plus and 2 minus connections)
    230 V AC-connection M6 bolts M6 bolts Screw-terminal 13mm2
    (6 AWG)
    M6 bolts 
    Weight 34 kg / 75 lb 30 kg / 66 lb 19 kg / 42 lb  30 kg / 66 lb 
    Dimensions (H x W x D mm & inches) 8.5 x 14.0 x 11.2 in
    470 x 350 x 280 mm
    17.5 x 13.0 x 9.6 in
    444 x 328 x 240 mm
    14.3 x 10.2 x 8.6 in
    362 x 258 x 218 mm
    17.5 x 13.0 x 9.6 in
    444 x 328 x 240 mm
    STANDARDS        
    Safety EN 60335-1, EN 60335-2-29
    Emission Immunity EN55014-1, EN 55014-2, EN 61000-3-3
    1) Can be adjusted to 50 HZ     
    2) Protection key:
      a) output short circuit
      b) overload
      c) battery voltage too high
      d) battery voltage too low
      e) temperature too high
      f) 120 VAC on inverter output
      g) input voltage ripple too high
    3) Non linear load, crest factor 3:1
    4) At 77  ÌŠF ambient
    5) Switches off when no external AC source available
    6) Programmable relay that can be set for general alarm,
       DC undervoltage or genset start/stop function
       AC rating: 120V / 4A
       DC rating: 4A up to 35VDC, 1A up to 60VDC
    7) A. o. to communicate with a Lithium Ion battery BMS
     
    For more information:
    Victron Quattro 3000 or 5000 manual